Differentiated photometric determination of chlorine according to AWWA 4500-Cl G / EN ISO 7393-2
- Continuous and simultaneous analysis of free, bound and total chlorine
- Freely adjustable measuring intervals for optimized use of reagents
- Fast and easy to use verification with user-friendly solid state standard
Specifications
Differentiated photometric determination of chlorine according to AWWA 4500-Cl G / EN ISO 7393-2
| Disinfectant measurement | Measuring range [ppm] | Accuracy | |
| Free Chlorine, monochlorine, total residual chlorine | 0.00 | 1.00 | ±0.01 ppm |
| 1.00 | 3.00 | ±0.06 ppm | |
| 3.00 | 5.00 | ±0.2 ppm | |
| Combined chlorine | Calculated difference of total residual chlorine and free chlorine. | ||
| Measurement time | 2 min. |
| Cycle time free chlorine | 1 … 12 min. |
| Cycle time total residual chlorine | 6 … 60 min. |
| pH measuring range | 2 … 12 |
| Temperature measuring range | -30 … 100 °C |
| Transmitter Specifications | |
| Power Supply | 100-240 VAC (±10%), 50/60Hz or 10-36 VDC |
| Power consumption | max. 35 VA |
| Sample conditions | |
| Water consumption | min. 10 l/h |
| Water inlet pressure | 0.15 … 2 bar |
| Sample temperature | 5 … 50 °C |
| Panel | |
| Dimension | 400 x 850 x 200 mm |
| Material | PVC |
| Weight | 9.0 kg |
Contact us to place an order.
Downloads
| Downloads | Click Here |