High-sensitivity online analyser for continuous monitoring of oil and polycyclic aromatic hydrocarbons in water.
The AMI-II Fluotrace Oil is a high-precision fluorescence analyser for the continuous measurement of oil and polycyclic aromatic hydrocarbons (PAH) in water. Using UV fluorescence technology, it detects very low hydrocarbon concentrations with a typical response time of less than six seconds. The low-maintenance system is suitable for pure water, potable water, cooling water, return condensate, surface water, seawater treatment and effluent monitoring, providing reliable real-time data to support water quality control and the early detection of oil contamination.
Specifications
- High-precision UV fluorescence measurement for continuous monitoring of oil and polycyclic aromatic hydrocarbons in water.
- Detects low concentrations with a typical limit of detection of 0.15 ppm oil or 5 ppb PAH.
- Fast response time of less than six seconds for early detection of hydrocarbon contamination.
- LED technology provides long-term measurement stability without routine light-source replacement.
- Titanium sensor shaft provides durability across diverse water applications.
- Manual verification using high-precision standards.
- Low-maintenance system supplied on a panel and ready for installation and operation.
AMI-II Fluotrace Oil Specifications
The AMI-II Fluotrace Oil is a high-precision fluorometer for the continuous measurement of oil and polycyclic aromatic hydrocarbons in water.
The analyser uses a UV fluorescence sensor with excitation at 255 nm and detection at 360 nm. It is suitable for pure water, potable water, cooling water, return condensate, surface water, seawater treatment and effluent monitoring.
The complete system is mounted on a PVC panel, tested and ready for installation and operation.
Fluorescence measurement
| Measurement principle | UV fluorescence |
| Excitation wavelength | 255 nm |
| Detection wavelength | 360 nm |
| Accuracy | ±10% of the measured value + 5 ppb |
| Response time | Less than 6 seconds (t90) |
PAH measurement
| Measuring range | 0.00 to 9.99 ppb |
| Resolution | 0.01 ppb |
| Measuring range | 10.0 to 999.9 ppb |
| Resolution | 0.1 ppb |
| Measuring range | 1000 to 5000 ppb |
| Resolution | 1 ppb |
| Limit of detection | 5 ppb PAH |
Oil measurement
| Measuring range | 0.00 to 9.99 ppm |
| Resolution | 0.01 ppm |
| Measuring range | 10.0 to 150.0 ppm |
| Resolution | 0.1 ppm |
| Typical limit of detection | 0.15 ppm oil |
Sample conditions
| Flow rate | Approximately 5 to 50 L/h |
| Temperature | Up to 40 °C |
| Inlet pressure at 25 °C | Up to 1 bar |
| Outlet pressure | Pressure-free |
Power supply
| AC version | 100–240 VAC (±10%), 50/60 Hz (±5%) |
| DC version | 10–36 VDC |
| Power consumption | Maximum 35 VA |
Panel
| Dimensions | 280 × 850 × 200 mm |
| Material | White PVC |
| Total weight | 7.7 kg |
Contact us to place an order.
Downloads
| Brochure | Product Flyer |
| Manual | |
| Datasheet | Datasheet |