Monitor AMI-II Deltacon Power

AMI-II Deltacon Power

Dual-channel analyser for continuous measurement of specific conductivity and cation conductivity with an integrated cation resin column.

The AMI-II Deltacon Power is a dual-channel analyser for continuous monitoring of specific conductivity (SC) and cation conductivity after cation exchange (CACE). Using differential conductivity, it calculates the sample pH and alkalising reagent concentration. Designed for power plants and industrial water systems, it provides accurate, real-time data to support optimal water chemistry and help protect critical plant components.

Specifications

  • Complete system with transmitter, two conductivity sensors, flow cell, digital flow meter and cation resin column.
  • Transparent, easily replaceable cation resin column with automatic deaeration.
  • Calculates resin consumption and provides an integrated exhaustion alarm.
  • Fast response time following start-up.
  • Calculates the sample pH value and alkalising reagent concentration.
  • Integrated self-diagnostics support measurement validation and reliable operation.

 

AMI-II Deltacon Power Specifications

The AMI-II Deltacon Power includes the AMI-II Deltacon Power transmitter, two UP-Con1000-SL conductivity sensors and a Catcon-Plus-SL flow cell. The complete system is mounted on a stainless steel panel and is ready for installation and operation.

The transmitter includes two signal outputs for measured values or continuous control, two relays configurable as limit switches or controllers, an alarm relay for summary alarm indication and an input for a potential-free contact.

The flow cell is equipped with a manual flow adjustment valve, digital sample flow meter and integrated cation exchanger vessel with automatic deaeration.

A pre-rinse configuration with a second resin vessel is available as an option.

 

Measuring ranges

Conductivity 0.055 to 1000 µS/cm
Calculated pH pH 7.5 to 11.5
Calculated ammonia 0.01 to 10 ppm

Sample conditions

Temperature Up to 50 °C
Inlet pressure Up to 2 bar
Outlet pressure Pressure-free atmospheric drain

Sample connections

Inlet Swagelok ¼" tube adapter
Outlet G ½" adapter for flexible tube 20 × 15 mm

Power supply

AC version 100–240 VAC (±10%)
DC version 10–36 VDC

Please note: cation exchange resin is not included because of its limited shelf life and must be ordered separately.

 

Contact us to place an order.

Downloads

Brochure
Manual Manual
Datasheet Datasheet
<< return to products